General information
1-39
ELECTRIC FIELD PROBE EP-300
Frequency range
100 kHz - 3 GHz
Level range
0.1 - 300 V/m
Overload
> 600 V/m
Dynamic range
> 66 dB (typical >70 dB)
Resolution
0.01 V/m
Sensitivity
0.15 V/m (typical >0.1V/m)
Absolute error @ 50 MHz 20 V/m
±
0.8 dB
Flatness (10 - 300 MHz)
±
0.5 dB
Flatness (3 MHz - 3 GHz)
±
1.5 dB
Isotropicity
±
0.8 dB (typical
±
0.5 dB @ 930 and 1800 MHz)
H-field rejection
>20 dB
20°C ÷ 60°C = ± 0.1 dB
Temperature error
0°C ÷ 20°C = -0.05 dB/°C
-20°C ÷ 0°C = -0.15 dB/°C
Calibration
Internal into E
2
PROM
Size
317 mm length, 58 mm diameter
Weight
100 g
Fig. 1-32
EP-300 probe
Typical frequency response for EP-300 probe
@20V/m
-6.0
-5.0
-4.0
-3.0
-2.0
-1.0
0.0
1.0
0.1
1
10
100
1000
10000
[MHz]
[dB]