1-14
General information
QUAD-BAND ELECTRIC FIELD PROBE EP-4B-02
Wide band
EGSM 900 Band pass
EGSM 1800 Band pass
UMTS Band pass
Frequency range
0.1 – 7000 MHz
925 – 960 MHz
1805 – 1880 MHz
2110 – 2170 MHz
Level range
0.2 – 200 V/m
0.03 – 30 V/m
Dynamic range
> 60 dB
> 60 dB
Linearity
± 0.5 dB (0.5 to 100 V/m)
@ 50 MHz
± 0.5 dB (0.1 to 20 V/m)
Resolution
0.01 V/m
Sensitivity
0.2 V/m
0.03 V/m
Flatness @ 6 V/m
3 – 200 MHz +/-1.5 dB
0.15 MHz - 3 GHz +/-2 dB
0.1 MHz – 7 GHz +/- 3 dB
925 – 960 MHz
+0.5 / -2.5 dB
1805 MHz – 1880 MHz
+0.5 / -2.5 dB
2110 – 2170 MHz
+0.5 / -2.5 dB
Anisotropy @ 3 V/m
±
0.8 dB @ 50 MHz
(typical 0.6 dB)
±
0.8 dB @ 942.5 MHz
(typical 0.6 dB)
±
0.8 dB @ 1842.5 MHz
(typical 0.6 dB)
±
0.8 dB @ 2140 MHz
(typical 0.6 dB)
Out of band attenuation
not applicable
Rejection
to 1842 GSM = 25 dB
to 2140 UMTS = 25 dB
Rejection
to 942 GSM = 15 dB
to 2140 UMTS = 13 dB
Rejection
to 942 GSM = 17 dB
to 1842 GSM = 10 dB
H filed rejection
> 20 dB
Temperature error
0°C
÷
50°C =
±
0.3 dB -20°C
÷
0°C = - 0.1 dB / °C
Center frequency drift
not applicable
40°C
÷
60°C =
±
100 kHz -20°C
÷
40°C = -100 kHz / °C
A/D conversion
On board
Calibration factors
On board E
2
prom
Temperature sensor
On board
Size
Length 450 mm, diameter 55 mm
Weight
210g
Fig. 1-9
EP-4B-02 probe
Summary of Contents for LR-01
Page 72: ...2 12 Installation and use This page has been left blank intentionally...
Page 76: ...3 4 Probes Manager software installation Click Next to proceed installing...
Page 116: ...5 4 Firmware Update This page has been intentionally left blank...
Page 168: ...9 40 Command protocol This page has been left blank intentionally...
Page 192: ...11 4 Service This page has been left blank intentionally...
Page 194: ...Suggerimenti Commenti Note Suggestions Comments Note...