9-30
Command protocol
SRST
This setting command restores the default configuration.
The command resets the main parameters as follows:
•
All Alarms masked;
•
Averaging period of 6 minutes;
•
Running average cleared;
•
Averaging type: RMS;
The reply RST=OK indicates that the command has been granted.
Example:
#LRSRST*
restarts the unit.
SRSTR
This setting command restores the default configuration, logger rate included.
The command resets the main and logger parameters as follows:
•
Logger rate of 6 minutes;
•
All Alarms masked;
•
Averaging period of 6 minutes;
•
Running average cleared;
•
Averaging type: RMS;
The reply “Reset to Default Factory Setting and Reboot” indicates that the command has
been granted, and is followed by the restarting diagnostics.
Note: extreme attention must be used as this command invalidates any data already
stored making them meaningless.
Example:
#LRSRSTR*
resets the logger and restarts the unit.
SSID
i
This setting command sets the Wi-Fi network name for wireless 802.11 b/g/n connection.
i is an alphanumeric string, up to 64 characters long.
The parameter is kept also when the unit is switched OFF.
The reply is:
SID=OK if the command has been granted
SID=ERR if the command has been refused
Example:
#LRSSIDNardaWIFI*
which means that the SSID of the access point to
connect to is NardaWIFI.
SSTSx
(for EHP-2B
model
probe only)
Set the reference standard for EHP-2B probe
The format is as follows:
#LRSSTSx*
where
X
is an index that goes from 1 to 4:
“1” = Standard 1 (ICNIRP98OCC for EHP-2B-01/02/05/06 and ICNIRP2020OCC for 03/04/07/08)
“2” = Standard 2 (ICNIRP98GP for EHP-2B-01/02/05/06 and ICNIRP2020GP for 03/04/07/08)
“3” = Standard 3 (SC6CONTR for EHP-2B-01/02/05/06 and FCCCONTR for 03/04/07/08)
“4” = Standard 4 (SC6UNCONTR for EHP-2B-01/02/05/06 and FCCUNCONTR for 03/04/07/08)
Example
#LRSSTS1*
returns the response:
#LRSSTS=OK*
confirming that the EHP-2B probe is set to Standard 1.
This index represents the reference standard for alarms, warnings, report and ?MES
command response.
The index is permanent and stored in the Flash.
If the index entered is not correct, the response string is:
STS=SERR
Summary of Contents for LR-01
Page 72: ...2 12 Installation and use This page has been left blank intentionally...
Page 76: ...3 4 Probes Manager software installation Click Next to proceed installing...
Page 116: ...5 4 Firmware Update This page has been intentionally left blank...
Page 168: ...9 40 Command protocol This page has been left blank intentionally...
Page 192: ...11 4 Service This page has been left blank intentionally...
Page 194: ...Suggerimenti Commenti Note Suggestions Comments Note...