8.2 Installation of the CFDL Controller
8.2 Installation of the CFDL Controller
8.2.1
Ambient condition
The condition of CFDL controller is same as CFD controller.
Please refer to “2.2.1 Ambient condition”.
8.2.2
Installation procedure and place
(1) Make sure to install the intake and exhaust port 200mm or more away from the wall.
(2) Install the controller so that the height of power switch from work floor will be 0.6m to 1.9m.
(3) CFDL controller is not dust-proof or drip-proof structured.
In case of using it under the dust or mist environment then, please add the following option “Controller
protection box”. In case of using the protection box, the condition of the ambient temperature is 0 to 30
℃
For CFDL1 / CFDL2
CFD-OP133-A
(Supports protection level IP54)
For CFDL4
CFDL-OP133-A
(Supports protection level IP54)