3
Machine Parameter 12
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
ADF scanner registration
adjustment (Horizontal)
Adjusts the start point to
scan the document.
The plus setting increases
the left margin and the minus
setting decreases it.
Each setting changes by
0.5 mm.
Switch 76543210 Settings
00000111 3.5
mm Maximum
00000110 3.0
mm
00000101 2.5
mm
00000100 2.0
mm
00000011 1.5
mm
00000010 1.0
mm
00000001 0.5
mm
00000000 Standard
←
Initial setting
10000001 -0.5
mm
10000010 -1.0
mm
10000011 -1.5
mm
10000100 -2.0
mm
10000101 -2.5
mm
10000110 -3.0
mm
10000111 -3.5
mm Minimum
Machine Parameter 14 <- F-320 Only)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Adjustment of the scanning
width (ADF)
Adjust the scanning width
with this switch.
Adding the plus setting
widens the scanning width
and the minus setting
narrows scanning width.
Each setting changes by
0.085 mm.
Switch 76543210 Settings
00111111 + 5.355 mm Maximum
00111110 + 5.270 mm
00111101 + 5.185 mm
00000010 + 0.170 mm
00000001 + 0.085 mm
00000000 standard
←
Initial setting
10000001
−
0.085 mm
10000010
−
0.170 mm
10111101
−
5.185 mm
10111110
−
5.270 mm
10111111
−
5.355 mm Minimum