7
Machine Parameter 50
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Adjustment of the scanning
stretching and squeezing for
ADF (Horizontal)
The plus setting stretches the
image data and the minus
setting squeezes it.
Each setting changes by
0.1%
Switch 76543210 Settings
01111111 12.7 % Maximum
:
00100000 3.2 %
:
00011000 2.4 %
:
00010000 1.6 %
:
00001000 0.8 %
:
00000000 0.0 %
←
Initial setting
:
10001000 -0.8 %
:
10010000 -1.6 %
:
10011000 -2.4 %
:
10100000 -3.2 %
:
10111000 -12.7 % Minimum
Machine Parameter 51
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
1
2
0
1
0
0
1
Adjustment of the scanning
stretching and squeezing for
ADF. (Vertical)
The plus setting stretches the
image data and the minus
setting squeezes it.
Each setting changes by
0.1%
Initial setting TBD
Switch 76543210 Settings
01111111 12.7 % Maximum
:
00011000 2.4 %
:
00010000 1.6 %
:
00001001 0.9 %
←
Initial setting
:
00001000 0.8 %
:
00000000 0.0 %
:
10001000 -0.8 %
:
10010000 -1.6 %
:
10011000 -2.4 %
:
10111000 -12.7 % Minimum