3-3
Machine Parameter 00
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Country code
The country code enables the ROM to output the
correct programming information for the respective
country.
Machine Parameter 01
Switch
Initial
Setting
Adjust Usage/Comments
7
0
Not used
6
0
Not used
5
0
Not used
4
0
Not used
3 0
2 0
1 0
0 0
Output attenuation
See table below.
Note:
The setting of this switch is available only
when set at a value other than 0 dB. This setting is
used instead of Memory Switch 11, bit 3-0.
Machine Parameter 01…Output attenuation
Switch -15
dB
-14
dB
-13
dB
-12
dB
-11
dB
-10
dB
-9
dB
-8
dB
-7
dB
-6
dB
-5
dB
-4
dB
-3
dB
-2
dB
-1
dB
-0
dB
3
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0