3-1
Section3
Adjustment Procedures
3.1 Field Service Program Modes
The following table shows the maintenance functions.
Use these functions for maintenance and adjusting the machine parameters.
Note:
When you press “
*
” (asterisk), you will hear short beeps. However continue the operation, as it is not
a problem.
Function
Key pressing
Summary
Page
Machine parameters setting
MENU, *, 0, 0
Used to set or clear machine parameters.
3-2
Memory switches setting
MENU, *, 0, 1
Used to set or clear memory switches.
3-26
Clear programmed data / user
settings
MENU, *, 0, 2
Erases user-programmed information (date, time,
TTI, autodialer, etc.) and any documents stored in
memory.
3-102
All RAM clear
MENU, *, 0, 3
Erases same information as “Clear Programmed
Data / User Settings” function along with resetting
all of Memory switches and Unique switches to
factory defaults.
3-102
Unique switches setting
MENU, *, 0, 4
Used to set or clear unique switches.
3-54
Printer maintenance
MENU, *, 0, 6
Access this mode to determine the cause of the
“Please Call Service” error message.
Or, when replacing the Fuser unit or Image
transfer roller, reset the counter using this mode.
3-99
Monitor speaker ON/OFF
MENU, *, 0, 8
Monitor the signals during the fax transaction.
Test functions
MENU, *, 0, 9
Allows the technician to perform a series of
diagnostic tests.
3-105
Print parameter list
MENU, *, 1, 0
Prints a list of the machine switch settings
showing the default settings and current settings.
3-109
Factory test functions
MENU, *, 1, 1
Allows the technician to perform a series of
diagnostic tests.
3-109
Telephone circuit test modes
MENU, *, 1, 2
Allows the technician to perform a series of
diagnostic tests.
3-114
-----
MENU, *, 1, 3
Not used.
---
-----
MENU, *, 1, 4
Not used.
---
Consumable order sheet
setting
MENU, *, 1, 5
Used to set or clear the consumable order sheet.
3-118
DRAM Clear
MENU, *, 1, 6
Used to clear a DRAM.
3-120
Clear life monitor
MENU, *, 1, 7
Used to clear the Life monitor, which keeps a
count of the pages scanned, printed, etc.
3-120
-----
MENU, *, 1, 8
Not used.
---
Life monitor passcode
MENU, *, 1, 9
Used to protect the clear a Life monitor mode.
3-121
Life monitor maintenance
MENU, *, 2, 0
When the main control PCB has been replaced,
you should register the previous counter values of
the life monitor.
3-122
-----
MENU, *, 2, 1
Not used.
---
Sensor input test
MENU, *, 2, 2
Sensor diagnostic test.
3-124
Printer diagnostic mode
MENU, *, 2, 3
Printer diagnostic test.
3-125
Internet Fax mode
MENU, *, 2, 4
For optional IF-300 (Internet fax kit)
3-126
Update the Software
-----
Describes how to update the software.
3-129
Flash ROM polling
MENU, *, 2, 5
Down load the latest software by polling.
3-131
Flash ROM polling (Host)
MENU, *, 2, 6
Set the software version for Flash ROM polling.
3-131