3.4 Unique Switch Adjustment
3.4.1 Setting the Unique Switches
These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press
MENU, *, 0, 4.
2. Select the desired unique switch using numeric keypad or cursor key, and then press
[Enter]
.
Important: The bits are numbered 7 through 0 --- bit 7 is left most.
3. To navigate through the memory switch settings:
•
Press
key to move the cursor to the left.
•
Press
>
to move the cursor to the right.
•
Press the
0
(zero) or
1
on the numeric keypad to change the bit value.
•
Press
[Enter]
to save the setting of the displayed unique switch and advance to the next unique
switch. (If you want to cancel the setting of the displayed unique switch without saving, press
[Cancel]
.)
•
Press
STOP
to return the unit to standby.
Note:
You can confirm the initial setting of each Unique switch by the Unique Switch List.
The Unique Switch List will be printed by pressing
MENU, *, 1, 0.
3.4.2 Clearing the Unique Switch
Resets the unique switches to factory defaults.
1. From standby, press
MENU, *, 0, 4.
2. Press
[Clear].
3. Press
[Enter]
to reset the all unique switches to the factory defaults.
Note:
If you want cancel the clearing the unique switches, press
[Cancel]
.
Note:
To return to the standby mode, press
STOP
.