background image

INSTRUCTIONS

CODED FUNCTION SYSTEM

This instruction manual is for the Olympus Coded Function System. To ensure the safety, obtain optimum 
performance and to familiarize yourself fully with the use of this system, we recommend that you 
study this manual and the manuals of units used in combination with this system thoroughly before 
operating the system.
Retain this instruction manual in an easily accessible place near the work desk for future reference.

U-5RES-ESD

U-D5BDRES-ESD

U-D7RES

BX3-RFAS

U-HSEXP

U-CBS

A X 7 8 7 7

Summary of Contents for U-5RES-ESD

Page 1: ...liarize yourself fully with the use of this system we recommend that you study this manual and the manuals of units used in combination with this system thoroughly before operating the system Retain this instruction manual in an easily accessible place near the work desk for future reference U 5RES ESD U D5BDRES ESD U D7RES BX3 RFAS U HSEXP U CBS A X 7 8 7 7 ...

Page 2: ...g indicates compliance with the above directives In accordance with European Directive 2002 96 EC on Waste Electrical and Electronic Equipment this symbol indicates that the product must not be disposed of as unsorted municipal waste but should be collected separately Refer to your local Olympus distributor in EU for return and or collection systems available in your country ...

Page 3: ... READOUT EXTERNAL TRANSMISSION OF CODED INFORMATION 10 Page CONTENTS 1 BX43 System with LED Lamp Housing 7 2 BX43 System with Halogen Lamp Socket 8 3 BX53 System 9 CODED FUNCTION SYSTEM When using Industrial Microscope Frames such as BX41M LED BX51 51M GX51 71 or STM6 refer to manual U 5RES ESD U D5BDRES ESD for detailed installation instructions ...

Page 4: ... position 2 For safety always use the provided AC adapter to power the system 3 Keep the cables away from the lamp housing and the surroundings Otherwise the cables may melt and cause an electric shock hazard 4 Application of excessive force to the cables such as by pulling may cause damage So never apply such force to the cables Safety Symbol The following symbol is found on the system Study the ...

Page 5: ...ion never attempt to open disassemble or modify any part of the system 5 Before disposing of this product be sure to follow the regulations and rules of your local government If the system is used in a manner not specified by this manual the safety of the user may be imperiled In addition the system equipment may also be damaged Always use the system as outlined in this instruction manual The foll...

Page 6: ...S ESD U D5BDRES ESD connector BX3 RFAS connector POWER switch ON Depressed position OFF Out position Microscope frame hangers top bottom RS 232C connector Option connector The U CBM can be connected U HSEXP connector For the external DP21 exposure button AC adapter input connector ...

Page 7: ...les make sure that the POWER switch of the U CBS control box is set to OFF out position Hold each connector in the appropriate orientation and insert it all the way into the connector If a connector is provided with clamping screws be sure to tighten them Do not insert a non designated connector Otherwise the connector may be damaged CAUTION Coded Fluorescence Illuminator BX3 RFAS Microscope Frame...

Page 8: ...ers 3 on the rear of the microscope frame Fig 2 When using coded revolving nosepiece U 5RES ESD U D5BDRES ESD place U CBS on the table Refer to manual of coded revolving nosepiece Note 4 When this system is used with the DP21 microscope digital camera set the power switches to ON in the order of U CBS and 2 DP21 CB Otherwise the DP21 will not recognize the U CBS Also if the U D7RES U 5RES ESD or U...

Page 9: ...ter x1 In the subsequent pages the positions for attaching the cable holders and the method of cable distribution will be described for each microscope system The number of the cable holders used vary depending on the modules used in the system If the cable holders are attached in widely deviated positions the cable may become unable to reach the connector Be sure to attach the cable holders while...

Page 10: ... label Align with the height of line drawn on the label Align with the top right corner of the label Banding band Provided with U HSEXP Only either cable should be used U D7RES cable BX3 RFAS cable RS 232C cable AC adapter cable U HSEXP cable for right side installation U HSEXP cable for left side installation ...

Page 11: ...nd Provided with U HSEXP Only either cable should be used Align with the top left corner of the label Remove lamp cable slack before closing the holder Align with the height of line drawn on the label U D7RES cable BX3 RFAS cable RS 232C cable U LS30 5 lamp cable U HSEXP cable for right side installation U HSEXP cable for left side installation AC adapter cable ...

Page 12: ...ith the position at about 10 mm to the right of the edge of the attaching surface Align with the top right corner of the label Banding band Provided with U HSEXP Only either cable should be used U D7RES cable BX3 RFAS cable RS 232C cable AC adapter cable U HSEXP cable for right side installation U HSEXP cable for left side installation ...

Page 13: ...232C cable This system enables the functions interlocked with the objective and mirror unit in use except for the DP21 such as increase in the exposure time control speed addition of magnification information to the shot images and automatic scale change according to objective It also enables automatic switching of the motorized illuminator and motorized condenser according to the objective select...

Page 14: ... switch from the area 3 indicated by in the figure near the coarse adjustment knob on the left or right 3 Clean the final fixing position with absolute alcohol remove the backing sheet from the round plate and apply it securely on the final fixing positi on If there is an article with magnetic field near the U HSEXP equip ment failure or malfunction may result So do not let such an article as list...

Page 15: ......

Page 16: ...rmany 3500 Corporate Parkway Center Valley Pennsylvania 18034 0610 U S A 491B River Valley Road 12 01 04 Valley Point Office Tower Singapore 248373 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia 5301 Blue Lagoon Drive Suite 290 Miami FL 33126 U S A Printed in Japan on September 05 2011 M 005 04 ...

Reviews: