Fault
code
Alarm text
Meaning
Task
078
LIM
INTERCOOLER
LEV.
Alarm from external charge-air
coolant level monitoring
(Depending on the corresponding measuring
point, which is read via CAN bus)
079
L Bin-EXTERN 3
Alarm from external binary
channel 3
(Depending on the corresponding measuring
point, which is read via CAN bus)
080
L Bin-EXTERN 4
Alarm from external binary
channel 4
(Depending on the corresponding measuring
point, which is read via CAN bus)
089
ENGINE SPEED
LOW
Engine speed lower than 200
rpm;
automatic engine shutdown
Re-start the engine (
090
IDLE SPEED LOW
Idle speed not reached within a
specified period;
Termination of starting procedure.
Note further alarms.
091
RUN UP SPEED
LOW
Run-up speed not reached within
a specified period;
Termination of starting procedure.
Note further alarms.
092
START SPEED
LOW
Starter speed not reached within
a specified period;
Termination of starting procedure.
Note further alarms.
093
PREHEAT TEMP.
LIMIT2
Coolant preheating temperature
too low during starting (2nd limit)
Termination of starting procedure
(depending on project design)
Check preheating pump / preheating system
(see manufacturer’s documentation).
094
PREHEAT TEMP.
LIMIT1
Coolant preheating temperature
too low during starting (1st limit)
Check preheating pump / preheating system
(see manufacturer’s documentation).
100
EDM NOT VALID
Check sum error of
measuring-point data in EDM
If fault occurs repeatedly: Contact Service.
101
IDM NOT VALID
Check sum error of
measuring-point data in IDM
If fault occurs repeatedly: Contact Service.
102
INVALID FUEL
CONS. 1
Check sum error of accumulated
fuel consumption data in EDM
(redundant data record 1)
If fault occurs repeatedly: Contact Service.
103
INVALID FUEL
CONS. 2
Check sum error of accumulated
fuel consumption data in EDM
(redundant data record 2)
If fault occurs repeatedly: Contact Service.
104
OP HOURS1 NOT
VALID
Check sum error of hour meter
data in EDM
If fault occurs repeatedly: Contact Service.
105
OP HOURS2 NOT
VALID
Check sum error of hour meter
data in IDM
If fault occurs repeatedly: Contact Service.
106
ERR REC1 NOT
VALID
Check sum error of fault memory
in EDM (redundant data record 1)
If fault occurs repeatedly: Contact Service.
107
ERR REC2 NOT
VALID
Check sum error of fault memory
in EDM (redundant data record 2)
If fault occurs repeatedly: Contact Service.
MS15009/00E 06-09
© MTU
Summary of Contents for Detroit Diesel 12 V 2000 P62
Page 18: ...14 Safety MS15009 00E 06 09 MTU...
Page 62: ...58 Operation MS15009 00E 06 09 MTU...
Page 188: ...184 Engine Governor Assignment and Circuitry MS15009 00E 06 09 MTU...
Page 196: ...192 Special Tools Part No Designation Use Qty F30025897 Socket wrench 1 MS15009 00E 06 09 MTU...
Page 198: ...194 Special Tools MS15009 00E 06 09 MTU...
Page 204: ...200 Annex MS15009 00E 06 09 MTU...
Page 208: ......