Operation
49
3.2
Putting the engine into operation after extended
out-of-service-periods (>3 months)
Preconditions
• Engine is stopped and starting disabled.
• MTU Fluids and Lubricants Specifications (A001061/..) are available.
Putting the engine into operation after extended out-of-service-periods (>3 months)
Item
Task
Engine
Depreserve (
→
MTU Fluids and Lubricants Specifications A001061/..).
Lube oil system
Check engine oil level (
Fuel prefilter
Prime (
Fuel prefilter, pressure gauge
Align adjustable pointer with position of pressure indicator (
Fuel system
Vent
Coolant circuit
If engine is out of service for more than one year, change engine coolant
Change charge-air coolant (
Coolant circuit
Check engine coolant level (
Check charge-air coolant level (
Coolant circuit
Preheat coolant with preheating unit.
ECU
Check plug-in connections (
Monitoring equipment
Carry out lamp test (see manufacturer’s documentation).
Engine/generator control
system
Switch ON;
Select operating mode, e.g. MANUAL OPERATION, AUTOMATIC OPERATION.