Checking flushing arms on oil
filter element for ease of move-
ment
Note:
Opening (2) is located on the filtered-oil side.
Ensure particular cleanness.
1.
Cover opening (2).
Note:
Constrict opening with a suitable cover.
2.
Blow compressed air into aperture (1).
3.
Check that flushing arm turns at sight glass
(3).
4.
If flushing arm does not turn, remove oil filter
element, disassemble, check again
(→ Page 227) and replace if necessary.
234 | Oil Filtration / Cooling | MS150123/01E 2017-05
TIM-ID: 0000069547 - 003