341 – AL Open Load Cylinder A1
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A1.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
342 – AL Open Load Cylinder A2
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A2.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
343 – AL Open Load Cylinder A3
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A3.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
344 – AL Open Load Cylinder A4
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A4.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
345 – AL Open Load Cylinder A5
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A5.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
346 – AL Open Load Cylinder A6
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A6.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
347 – AL Open Load Cylinder A7
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A7.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
348 – AL Open Load Cylinder A8
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A8.
1. Check wiring of affected injector (→ Page 268).
2. Contact Service.
106 | Troubleshooting | MS150123/01E 2017-05
TIM-ID: 0000077157 - 001