8.13.9 Exhaust pressure sensor – Measuring lines cleaning
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Cleaner (Snow-White 11-0)
X00054118
1
Cleaner (Hakupur 50/136)
X00056700
1
WARNING
Compressed air gun ejects a jet of pressurized air.
Risk of injury to eyes and damage to hearing, risk of rupturing internal organs!
• Never direct air jet at people.
• Always wear safety goggles/face mask and ear defenders.
WARNING
Cleaner is extremely caustic.
Risk of injury and suffocation!
• Avoid contact with eyes and skin.
• Do not inhale vapors and smoke.
• Do not eat, drink, smoke when working with cleaner.
• Wear protective clothing, gloves, and goggles / safety mask.
• Take measures against electrostatic charging.
NOTICE
Cleaning agents should not be left to take effect for too long.
Damage to components is possible!
• Observe manufacturer's instructions.
Exhaust pressure sensor – Measuring lines cleaning
1.
Clean all parts.
2.
Clean all metallic parts with cleaner (Snow-White 11-0), then rinse with cleaner (Hakupur 50/136).
3.
Blow out all components thoroughly with compressed air.
190 | Exhaust Gas Aftertreatment | MS150123/01E 2017-05
TIM-ID: 0000071478 - 001