400 – AL Open Load Digital Input 1
Cause
Corrective action
Open load detected at digital
input 1 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
401 – AL Open Load Digital Input 2
Cause
Corrective action
Open load detected at digital
input 2 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
402 – AL Open Load Digital Input 3
Cause
Corrective action
Open load detected at digital
input 3 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
403 – AL Open Load Digital Input 4
Cause
Corrective action
Open load detected at digital
input 4 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
404 – AL Open Load Digital Input 5
Cause
Corrective action
Open load detected at digital
input 5 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
405 – AL Open Load Digital Input 6
Cause
Corrective action
Open load detected at digital
input 6 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
406 – AL Open Load Digital Input 7
Cause
Corrective action
Open load detected at digital
input 7 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
407 – AL Open Load Digital Input 8
Cause
Corrective action
Open load detected at digital
input 8 of the ECU.
1. Check cabling (→ Page 268).
2. Contact Service.
110 | Troubleshooting | MS150123/01E 2017-05
TIM-ID: 0000077157 - 001