Note:
• Do not use lubricants to expediate assembly!
• The maximum tightening torque of 25 Nm must not be exceeded!
11.
Tighten V-band clamp (2) to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Nut
M8
Tightening torque
20 Nm
12.
Check that the clamp has settled into position, tap lightly all around with a rubber mallet then tighten once
again to specified tightening torque.
Installing maintenance access
doors
Note:
If possible, two mechanics should install the
maintenance access doors.
1.
Push maintenance access door (2) into upper
and lower clamps (in the direction of the ar-
row, see magnified detail).
Note:
Make sure to establish the upper and lower
clamping connections when pushing the door
through the clamps into place.
2.
Close the clamps (arrowed) of maintenance
access door (2).
3.
Push maintenance access door (1) into upper
and lower clamps (in the same direction of
the arrow, see magnified detail).
Note:
Make sure to establish the upper and lower
clamping connections when pushing the door
through the clamps into place.
4.
Close the clamps (arrowed) of maintenance
access door (1).
5.
Use the outside clamps (arrows on the left
side) to fasten the maintenance access door
at the housing.
Note:
If the CDC parameters are not reset, the
emission certification of the engine becomes
invalid.
6.
Reset using DiaSys®, see (→ dialog system
DiaSys® E531920/..).
198 | Exhaust Gas Aftertreatment | MS150123/01E 2017-05
TIM-ID: 0000071397 - 003