Emission values – Check
Note:
Open the exhaust gas test section and in-
stall/remove measuring equipment only
when the engine is at standstill.
1.
Apply the exhaust probe (1) at the measuring
point.
2.
Start engine.
3.
Approach the measuring point until a stable
operating state has been reached.
4.
Carry out measurement and read-off meas-
ured value for NO
x rel
(ppm).
5.
Compare the measured value with the appli-
cable national limit value, adjust exhaust
emissions in case of any deviation.
MS150098/03E 2018-04
| Operation | 57
TIM-ID: 0000063508 - 004