565 – AL L1 P-Intake Air after Filter A
Yellow alarm.
Associated parameter 2.0186.921
Cause
Corrective action
Pressure loss over air filter on A
side is too high.
u
Replace air filter (→ Page 175).
566 – AL L2 P-Intake Air after Filter A
Yellow alarm.
Associated parameter 2.0186.931
Cause
Corrective action
Pressure loss over air filter on A
side is too high.
u
Replace air filter (→ Page 175).
567 – AL L1 P-Intake Air after Filter B
Yellow alarm.
Associated parameter 2.0187.921
Cause
Corrective action
Pressure loss over air filter on B
side is too high.
u
Replace air filter (→ Page 175).
568 – AL L2 P-Intake Air after Filter B
Yellow alarm.
Associated parameter 2.0187.931
Cause
Corrective action
Pressure loss over air filter on B
side is too high.
u
Replace air filter (→ Page 175).
569 – AL SAM Missing Data Fault
Red alarm.
Associated parameter 2.1090.128
Cause
Corrective action
This alarm is activated if the ECU
does not receive some messages
to be transmitted from SAM.
Possible problem related to CAN
bus, SAM does not work properly
or a device connected to SAM
does not work properly so that
SAM cannot transmit the
messages from this device
successfully.
u
Check the cabling/connectors of the devices connected to SAM
and ECU bus. Replace devices as necessary.
MS150098/03E 2018-04
| Troubleshooting | 129
TIM-ID: 0000027858 - 002