1.4530.018 – Position Error
Red alarm. Initiated by F-Series.
Cause
Corrective action
Position demand and feedback do
not match
1. Check mechanical system.
2. Restart F-Series.
1.4530.019 – Run Enable not active
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
F-Series setting is not correct.
u
Check setting.
1.4530.020 – Spring Check Failed
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
F-Series setting is not correct.
u
Check setting.
1.4530.021 – Internal Fault
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
Hardware not ready for operation.
u
Restart F-Series.
1.4530.022 – CAN Fault
Red alarm. Initiated by F-Series.
Cause
Corrective action
CAN bus connection faulty.
u
Check cabling and setting.
1.4550.031 – A - Internal Fault
Red alarm. Initiated by ProAct of cylinder bank A.
Cause
Corrective action
Hardware not ready for operation.
u
Restart ProAct.
1.4550.032 – A - Stop commanded (Run/Stop)
Yellow alarm. Initiated by ProAct of cylinder bank A.
Cause
Corrective action
ProAct setting is not correct.
u
Check setting.
1.4550.033 – A - Input (Supply) Voltage Fault
Yellow alarm. Initiated by ProAct of cylinder bank A.
Cause
Corrective action
Upper or lower supply voltage
limit reached.
1. Check supply voltage.
2. Check cabling.
100 | Troubleshooting | MS150098/03E 2018-04