Connecting starter
1.
Connect cables to starter as marked.
2.
Screw nut (1) onto terminal 50 and tighten to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Nut
M5x0.8
Tightening torque
2.5 Nm ±0.5 Nm
3.
Screw nuts (2), (3), (4), (5) onto terminals 30, 30 b, 45, 31 and tighten to specified torque using a torque
wrench.
Name
Size
Type
Lubricant
Value/Standard
Nut
M12x1.75 Tightening torque
30 Nm ±3 Nm
4.
Check starter operation.
180 | Starting System | MS150098/03E 2018-04