231 – SD Camshaft Speed
Red alarm. engine shutdown.
Associated parameter 1.8004.499
Cause
Corrective action
Camshaft sensor faulty, short
circuit or wire break.
u
Check sensor and cabling (B1.1), replace as necessary. Error
cleared after restarting the engine.
232 – SD Charger 1 Speed
Yellow alarm.
Associated parameter 1.3011.128
Cause
Corrective action
Speed sensor of primary
turbocharger faulty, short circuit
or wire break.
u
Turbocharger speed sensor is not fitted at present.
233 – SD Charger 2 Speed
Yellow alarm.
Associated parameter 1.3011.129
Cause
Corrective action
Speed sensor of secondary
turbocharger faulty, short circuit
or wire break.
u
Turbocharger speed sensor is not fitted at present.
245 – SD ECU Power Supply Voltage
Red alarm.
Associated parameter 2.8006.589
Cause
Corrective action
Internal Engine Control Unit fault.
u
Replace ADEC Engine Control Unit.
266 – SD Speed Demand
Red alarm.
Associated parameter 2.8006.586
Cause
Corrective action
Speed setting signal can no longer
be transmitted from plant.
u
Check signal and cabling between plant and ADEC.
118 | Troubleshooting | MS150098/03E 2018-04
TIM-ID: 0000027858 - 002