Temposonics
®
R-Series
V
EtherNet/IP™
Operation Manual
I 11 I
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 7: Temposonics
®
RH5 with ring magnet, part 2
RH5-J-A/-V – RH5 with threaded flange M22×1.5 and Ø 12.7 mm rod
(connection type D58)
Port 1 L/A
L/A Port 2
A/F 46
48
(1.89)
17
(0.67)
Sensor electronics housing
68
(2.68)
Null zone
51
(2.01)
Stroke length
25…7620
(1…300)
Ø 25.4 (
Ø
1)
Threaded flange
»J«
:
M22×1.5-6g
Magnet
Ø 12.7
±0.
13
(Ø
0.5
±0.
01
)
Dead zone
73.6
(2.9)
RH5-B-A/-V – RH5 base unit for replacement
(connection type D58)
Port 1 L/A
L/A Port 2
48
(1.89)
17
(0.67)
Sensor electronics
housing
58
(2.28)
Null zone
61
(2.4)
Stroke length
25…7620
(1…300)
Dead zone
52 / 54 / 57**
(2.05 / 2.13 / 2.24)
* Stroke length 25…1575 (1…62): 52 (2.05) dead zone
Stroke length 1576…5000 (62.05…196.9): 54 (2.13) dead zone
Stroke length 5001…7620 (196.9…300): 57 (2.24) dead zone