Temposonics
®
R-Series
V
EtherNet/IP™
Operation Manual
I 28 I
7.2.4
Verify that the new sensor is listed in the I/O Configuration tree.
The MTS EtherNet/IP™ sensor is now added to the network and
connected, ready to use.
NOTICE
If the sensor is disconnected, a yellow warning sign (shown below)
will appear over the module icon.
Before you begin, you will need the sensors static IP address you
recorded in from step 6.2.7.
7.3.1
Open the RSLogix 500 software interface.
7.3.2
Open the controllers’ directory tree. Click I/O configuration,
then right click your network. Select “New Module”. The “Select
Module” window opens.
7.3.3
In the “Select Module” window, select “Generic Ethernet
Module” and press “OK”. The “New Module” window opens.
Fig. 41:
New module on the network
Fig. 42:
Add a new module to the RSLogix 5000 IO tree
Fig. 43:
Add a new Generic moduletree
7.3 Add sensor to I/O configuration without using EDS file