MyoBravo Bedienungsanleitung / Operators Manual
72
Programmes
Short relaxation programme for the improvment of the well being. Strengthens
the removal of harmful metabolic products. Especially suited for regeneration
during the lunch break or in the evening after a training day.
MOD = Modulating modus (Frequency and/or pulse range
change automatically in accordance with a
pre-given rhythm.
W/R
= intermittent operating and resting mode
CONT
= continuous mode
BURST = burst-mode
Modulation time = exponential
For example: Modulating time 10 seconds at a pulse range of 250 – 150 µs
means:
Start at 250 µs – exponential decrease (first fast then slow) down to 150 µs in
five seconds, then increase (first slow then fast) back to 250 µs. This complete
cycle lasts for 10 seconds.
Progr.: 23
Phase 1 Phase 2 Phase 3 Phase 4 Phase 5
Phase time
min
15
Mode
Mod
Frequency work
Hz
8-12
Frequency rest
Hz
Pulse width
µS
300-200
Modulation time
secs
10
Ramp up time
secs
Ramp down time
secs
Work time
secs
Rest time
secs
Alternating
Synchronous
Overall time
15 min