Detergent and Rinse-aid Pumps and Injection Points - 201HT
Refer to the photo below:
1. The chemical dispensing pump run and the tank fill adjustment screws are located on the
end of the chemical circuit board swing-out bracket.
2. It is not necessary to swing the bracket out to make adjustments, but if desired, remove
the mounting nut (A) and swing the bracket (B) out and to the right.
3. Refer to the next page for adjustment instructions.
A
B
B
Installation - 201HT
! VERY IMPORTANT !
Contact a chemical supplier for detergent and rinse-aid chemicals. The
chemical supplier must adjust the chemical dispensing pumps for water
hardness and food soil types.
! ATTENTION !
The amount of dispensed chemical is determined by the run time of the dispensing pump.
! VERY IMPORTANT !
INSPECT & REPLACE THE CHEMICAL DISPENSING PUMP SQUEEZE TUBES EVERY SIX MONTHS.
20
Summary of Contents for 201HT M4 Series
Page 26: ...Blank Page This Page Intentionally Left Blank 18...
Page 39: ...This Page Intentionally Left Blank Blank Page 31...
Page 44: ...Blank Page This Page Intentionally Left Blank 36...
Page 64: ...This Page Intentionally Left Blank Blank Page 56...
Page 70: ...Timer Board Connection Diagram 201HT 201LT 62...
Page 76: ...Blank Page This Page Intentionally Left Blank 68...
Page 77: ...Models 201HT 201LT Service Replacement Parts 201HT 201LT Service Replacement Parts 69...
Page 78: ...This Page Intentionally Left Blank Blank Page 70...
Page 80: ...72 Wash Pump Motor Assembly 201HT 201LT 1 11 12 2 3 4 5 7 8 9 10 6 13 14 15...
Page 85: ...Blank Page This Page Intentionally Left Blank 77...
Page 88: ...80 Fill Solenoid Valve 201HT 201LT 1 2 3 4 9 5 6 7 8...
Page 96: ...88 Booster Assembly 201HT Only 1 1 2 2 3 4 1 6 5 7 8 9 10 11 12 13 4 15 14...
Page 104: ...96 Control Panel 201HT Only 1 2 2 3 6 5 7 5 10 8 8 9 9 11 10 4...
Page 108: ...100 Panels 201HT 201LT 6 1 3 2 4 5 7 9 8 8...
Page 110: ...102 Door Assembly 201HT 201LT 1 4 5 6 6 7 7 9 9 8 2 3 3 5 10 10...
Page 112: ...104 Dish Racks Line Strainer PRV 201HT 201LT 1 2...
Page 114: ...This Page Intentionally Left Blank Blank Page 106...
Page 116: ...Electrical Schematic 201HT Only 108 SINGLE PHASE THREE PHASE 4 AMP FUSE 201HT...
Page 118: ...110 Timing Charts 201HT 201LT 201HT 201LT UL130...
Page 119: ......
Page 120: ......