201HT - Installation
! ATTENTION !
ALL DISHWASHERS ARE SHIPPED FROM THE FACTORY WIRED FOR SINGLE PHASE
OPERATION UNLESS SPECIFIED AT THE TIME OF ORDER.
IF YOU ARE CONVERTING A SINGLE PHASE MACHINE TO THREE PHASE BE SURE
TO FOLLOW THE BOOSTER WIRING INSTRUCTIONS ON PAGES 11-13.
Electrical Connections - 201HT with Built-in Booster
1PH and 3PH Wiring Diagrams
L1
L2
L3
N
208-230
VAC
0 VAC
0 VAC
115VAC
GRD
SINGLE PHASE POWER CONNECTION
Model 201HT with Booster
Do not connect power to L3
HOW TO CONNECT 1 PHASE POWER
! VERY IMPORTANT !
1. Check the data plate on the front of the
dishwasher for the phase of the machine.
.
2. Remove the lower access panel.
3. Pull power connection box forward and out.
4. The Main Terminal Block has connections
for L1, L2, L3, Neutral and Ground.
5. Connect ground, then connect
L1, L2 to 208-230VAC.
6. Connect a current carrying neutral to N.
7. Main Power connections are complete.
If the data plate says the machine is 1 Phase,
then connect a 1 PH power supply.
DO NOT CONNECT POWER TO L3.
THE ELECTRICAL POWER MUST BE A
3-WIRE PLUS GROUND SUPPLY WHICH
INCLUDES A CURRENT CARRYING NEUTRAL.
L1
L2
L3
N
208-230
VAC
208-230
VAC
208-230 VAC
115VAC
GRD
THREE PHASE POWER CONNECTION
Model 201HT with Booster
HOW TO CONNECT 3 PHASE POWER
1. Check the data plate on the front of the
dishwasher for the phase of the machine.
.
2. Remove the lower access panel.
3. Pull power connection box forward and out.
4. The Main Terminal Block has terminals for
L1, L2, L3, Neutral and Ground.
5. Connect ground, then connect
L1, L2, L3 to 208-230VAC.
6. Connect a current carrying neutral to N.
7. Main power connections are complete.
If the data plate says the machine is 3 Phase,
then connect a 3 PH power supply.
! VERY IMPORTANT !
THE ELECTRICAL POWER MUST BE A
4-WIRE PLUS GROUND SUPPLY WHICH
INCLUDES A CURRENT CARRYING NEUTRAL.
7
Summary of Contents for 201HT M4 Series
Page 26: ...Blank Page This Page Intentionally Left Blank 18...
Page 39: ...This Page Intentionally Left Blank Blank Page 31...
Page 44: ...Blank Page This Page Intentionally Left Blank 36...
Page 64: ...This Page Intentionally Left Blank Blank Page 56...
Page 70: ...Timer Board Connection Diagram 201HT 201LT 62...
Page 76: ...Blank Page This Page Intentionally Left Blank 68...
Page 77: ...Models 201HT 201LT Service Replacement Parts 201HT 201LT Service Replacement Parts 69...
Page 78: ...This Page Intentionally Left Blank Blank Page 70...
Page 80: ...72 Wash Pump Motor Assembly 201HT 201LT 1 11 12 2 3 4 5 7 8 9 10 6 13 14 15...
Page 85: ...Blank Page This Page Intentionally Left Blank 77...
Page 88: ...80 Fill Solenoid Valve 201HT 201LT 1 2 3 4 9 5 6 7 8...
Page 96: ...88 Booster Assembly 201HT Only 1 1 2 2 3 4 1 6 5 7 8 9 10 11 12 13 4 15 14...
Page 104: ...96 Control Panel 201HT Only 1 2 2 3 6 5 7 5 10 8 8 9 9 11 10 4...
Page 108: ...100 Panels 201HT 201LT 6 1 3 2 4 5 7 9 8 8...
Page 110: ...102 Door Assembly 201HT 201LT 1 4 5 6 6 7 7 9 9 8 2 3 3 5 10 10...
Page 112: ...104 Dish Racks Line Strainer PRV 201HT 201LT 1 2...
Page 114: ...This Page Intentionally Left Blank Blank Page 106...
Page 116: ...Electrical Schematic 201HT Only 108 SINGLE PHASE THREE PHASE 4 AMP FUSE 201HT...
Page 118: ...110 Timing Charts 201HT 201LT 201HT 201LT UL130...
Page 119: ......
Page 120: ......