201HT Only - Digital Temperature Display Codes
DISPLAY CODES
WASH TEMP
RINSE TEMP
WASH TEMP
RINSE TEMP
RINSE TEMP
WASH TEMP
Booster Display Codes
CAUSE
Booster overtemp lockout
because booster temperature
is greater than 210˚F.
NOTE:
Booster is locked out
for 10 minutes before being
re-energized.
Booster therrmistor is
defective or disconnected,
broken wires.
NOTE:
After the therrmistor
is reconnected, there is a 5
second delay before the
display is re-energized.
Error Codes for Booster and Final Rinse Thermistors Only.
1 5 0
1 5 0
1 5 0
Both booster and final rinse
display thermistors are
defective, unplugged, or open
or broken wires between the
display and thermistor.
NOTE:
After a therrmistor
is reconnected, there is a 5
second delay before the
display is re-energized.
H
61
Summary of Contents for 201HT M4 Series
Page 26: ...Blank Page This Page Intentionally Left Blank 18...
Page 39: ...This Page Intentionally Left Blank Blank Page 31...
Page 44: ...Blank Page This Page Intentionally Left Blank 36...
Page 64: ...This Page Intentionally Left Blank Blank Page 56...
Page 70: ...Timer Board Connection Diagram 201HT 201LT 62...
Page 76: ...Blank Page This Page Intentionally Left Blank 68...
Page 77: ...Models 201HT 201LT Service Replacement Parts 201HT 201LT Service Replacement Parts 69...
Page 78: ...This Page Intentionally Left Blank Blank Page 70...
Page 80: ...72 Wash Pump Motor Assembly 201HT 201LT 1 11 12 2 3 4 5 7 8 9 10 6 13 14 15...
Page 85: ...Blank Page This Page Intentionally Left Blank 77...
Page 88: ...80 Fill Solenoid Valve 201HT 201LT 1 2 3 4 9 5 6 7 8...
Page 96: ...88 Booster Assembly 201HT Only 1 1 2 2 3 4 1 6 5 7 8 9 10 11 12 13 4 15 14...
Page 104: ...96 Control Panel 201HT Only 1 2 2 3 6 5 7 5 10 8 8 9 9 11 10 4...
Page 108: ...100 Panels 201HT 201LT 6 1 3 2 4 5 7 9 8 8...
Page 110: ...102 Door Assembly 201HT 201LT 1 4 5 6 6 7 7 9 9 8 2 3 3 5 10 10...
Page 112: ...104 Dish Racks Line Strainer PRV 201HT 201LT 1 2...
Page 114: ...This Page Intentionally Left Blank Blank Page 106...
Page 116: ...Electrical Schematic 201HT Only 108 SINGLE PHASE THREE PHASE 4 AMP FUSE 201HT...
Page 118: ...110 Timing Charts 201HT 201LT 201HT 201LT UL130...
Page 119: ......
Page 120: ......