AGITO
AGITO User Manual OS 5.0 Nova
44 - Operation
It is recommended that if full-speed (1400 rpm) operation is required that a minimum of 4.5m of track is reserved at each end of the track.
Until Dynamic Breaking is introduced this will limit the amount of track available for use at slower speeds.
WHEN POSITIONING THE MAG-STOP MAGNETS REMEMBER TO COMPENSATE FOR THE LENGTH OF THE AGITO
SYSTEM, I.E. QUOTED STOPPING DISTANCES WILL BE +1M FROM THE NON-MAG-SENSE END OF THE AGITO.
»
TRAX MODE: USING TOWER
When operating Tower in Trax mode it is possible to limit the range of movement. To access this function, press the dial to change the
function mode.
STEER LIMIT enables TOWER LIMITS (Top and Bottom)
It is possible to set range limits on the Tower, once the Tower Limit – Top or Bottom has been
selected the percentage will switch to show the range. 0% bottom, 100% top. When the
relevant limit is selected the display will turn green whilst it is adjustable.
STEER RATE enables TOWER SPEED
Once STEER RATE now adjusts TOWER SPEED control, the Master display will show Tower
Position.
»
DRIVE DYNAMICS: TRAX MODE
With your batteries installed, Hub Box and Pedals connected, it is good practice to first turn on your MASTER Controller. Now on the
chassis pull up the red Power button on the top of the CORE. Select Trax Mode from the Top-level menu, the Connection screen will now
be displaced and the start-up initialisation sequence will begin, see “Connect / Calibration Screen (Trax Mode)” on page 24. The
MASTER will ask the user to calibrate the Trax System, once this is selected the Menu will display the calibration sequence. At the end of
this sequence the CORE is fully powered on and ready to go. The MASTER will show the main Trax Mode Operation screen, see “Home
Screen (Trax Mode)” on page 24