AGITO
AGITO User Manual OS 5.0 Nova
54 - Operation
»
TOWER: POWER & FIBRE PASS-THROUGH
»
OVERVIEW
The AGITO Tower is supplied with power pass-through and optionally with a dual single-mode Fibre Optic upgrade.
»
POWER PASS-THROUGH
The Tower is equipped internally with a 3-core power line. This can be used when combined with one of three cable sets to allow up to two
different voltages to be passed from the base of the tower to the top. Shown as the “A” connectors in the two images below.
ARRI SRH-3 & SRH-360
The MI SRH cable set (AG-TO-801) is wired to provide both 12Vdc and 24Vdc circuits from the standard ARRI High Capacity cables
commonly supplied. The Arri manual provides details of recommended batteries, power solutions and wiring requirements.
The following cable is required when using the AGITO Mains PSU:
• SRH High Capacity Battery Power Cable 12V/24V, 0.5m/1.64ft (K2.0019306)
SHOTOVER G1
The MI G1cable set (AG-TO-802) is wired to provide a 48Vdc circuit from the standard SHOTOVER G1 Lemo Power Cable. The Shotover
manual provides details of recommended batteries, power solutions and wiring requirements.
OTHER REMOTE HEADS
If you intend to use another remote head, the MI Bare-ends cable set (AG-TO-809) provides bare-ends for custom configurations. The
internal wiring uses standard 1.5mm
2
cores.
»
OPTIONAL SINGLE-MODE FIBRE OPTIC UPGRADE
The optional Fibre Optic tower is supplied with two single-mode fibre optic cores, terminated to custom LEMO connectors. Each tower
is supplied with 4x Lemo - ST tails, additional or replacement cables are available, please contact your local sales rep for pricing. ST
connectors are industry standard and can be used to connect to any number of accessories from providers including BlueBell Opticom.
»
TOWER: STANDALONE OPERATION
»
TOWER SPREADER BASE
We highly recommend the use of our Tower Spreader Base when using the AGITO Tower in a standalone application. The plate includes
access to the 12v Power input via 4-pin XLR.
»
TOWER HAND CONTROLLER
When operating the Tower as a standalone unit, you will need the Tower Hand Controller unit providing cabled control of the tower
functions.