Hardware Installation & Configuration
Gemini 720is Imaging Sonar
Document: 0703-SOM-00002, Issue: 7
17
© Tritech International Ltd.
MAIN
AUX
MAIN
Bulkhead
view
Pin
Function
Pin
Function
AUX
Bulkhead
view
1
Ethernet Rx+
1
Ethernet Rx+
2
Ethernet Rx-
2
Ethernet Rx-
3
Ethernet Tx+
3
24V DC +
4
DC +
4
0V DC
5
N/C
5
Ethernet Tx+
6
Ethernet Tx-
7
DC Ground
5
6
4
1
2
3
7
8
8
N/C
6
Ethernet Tx-
6
5
4
1
2
3
S11017 (1000m) or S11027 (4000m)
Gemini 720is fitted with two Seacon 55 series connectors. The main connector uses Ethernet
or VDSL communications with the auxiliary connector allowing either RS232 or RS485
(software selectable) communications to an attached device. A regulated 24V DC output is
also available.
MAIN
AUX
MAIN
Bulkhead
view
Pin
Function
Pin
Function
AUX
Bulkhead
view
1
Ethernet Rx+
1
RS232 Rx /
RS485 B
2
Ethernet Rx-
2
RS232 Tx /
RS485 A
3
Ethernet Tx+
3
24V DC +
4
DC +
4
0V DC
5
VDSL +
5
RS232 / TTL
Ground
6
Ethernet Tx-
7
DC Ground
5
6
4
1
2
3
7
8
8
VDSL -
6
TTL In
6
5
4
1
2
3
3.4. Surface Adapter Pin-out Diagrams
Note
For all system types the connection to the surface computer or IT infrastructure
from the Gemini Hub, Ethernet or VDSL adapter should be via a shielded Cat5e
cable fitted with an RJ45 connector. The 72V VDSL Adapter Unit can also be
used in applications where long length power and communications is desirable
- for more information see the associated Product Manual:
0713-SOM-00003
available at
www.tritech.co.uk