1) Numeric keys
(1) In the case of a parameter having a decimal point unit: The input value is shifted from the right
and input.
Example) 0.0 → "1 input" → 0.1 → "2 input" → 1.2 → "3 input" → 12.3
(2) In the case of integer parameter: The input value is input shifted from the right.
Exam
ple) 0 → "1 input" → 1 → "2 input" → 12 → "3 input" → 123
2) minus key (-)
(1) When the parameter input range is minus: +/- toggles. The key is always valid.
Example) -
16.5 → "- input" → 16.5 → "- input" → -16.5
(2) When the parameter input range does not reach minus: minus key is invalid (no minus display)
Example) 3.2 → "Input" → 3.2 → "- input" → 3.2
3) ESC key
Returns the input value before change and returns to the normal screen.
4) C key
Clear to 0 which is currently input.
5) SET key
It reflects the input value and returns to the normal screen.
6) MAX / MIN indication
Displayable range of the specified parameter is displayed.
[X10]
:
Increase the sensitivity of the rotaly knob by 10 times. The color of the switch changes from white to yellow
while active. Press again to deactivate and switch to white.
[SET]
:
If you press the [SET] key while it is shown in green, the setting item value is confirmed. When the value
is changed with the rotaly knob or the numeric keypad, the color of the [SET] key changes from white to
green. At that time, press the [SET] key to confirm the set value. [ESC] or cancels the change with touch
other than the numeric keypad, without pressing [SET], the selection parameters are changed back to
original valueand and the [SET] switch returns to white.
Cursor(
△▽
)
:
Move the selection parameter on the LCD in the direction indicated by triangle.
[DEL]
:
In the [F1] profile edit screen, invalidate the set thickness point. When you tap [DEL] on the set point, the
[DEL] switch turns green. If you tap again the [DEL] switch, [DEL] is executed to invalidate the thickness
point and it becomes interpolation data between specified points before and after.
* When setting the accumulator, this switch changes to the [PURGE] function.
[SHIFT]
:
While this switch is pressed and "SHIFT" is in the active state (switch is yellow), the screen called by the
F1 to F5 switches becomes the setting screen. If you press this switch again or select one of the setting
screens of F1 to F5, "SHIFT" becomes inactive (switch is white). * Please refer to 1-2-6 for the protection
of setting screen transition