MRJ06301
1.
DigiPack
Ⅲ
Manual, Installation and
Maintenance
1-1.
CHANGES FROM J141-214A
The basic specifications of DigiPack
Ⅲ
(J141-215) are equivalent to conventional J141-214A.
There are the following major differences.
Changed from currnt VGA (480 x 640) to WXGA (1200 x 800) size
In addition, with touch screen conversion, operation by the conventional push button switch and
display by the LED are abolished, and it is changed to operation/display on the screen. (Excluding
rotary knob and power supply confirmation LED)
Considering availability, change the external storage device to USB memory. (It is not attached to
controller)
The following USB memory has been tested for operation. The operation can not be guaranteed
with USB memory other than these model numbers. We recommend that you select the same
model number as below when purchasing.
-HTU3A 16GBK
In addition, other than the above, you can refer to the list of USB memories being used without
problems by customers at the following URL:
https://www.moog.co.jp/products/controllers-software/blow-molding-controllers/digipack3.html
-tightened, and the terminal block was made detachable.
Mounting screw size is M3.5. Please use crimp terminal matching it.
Also, since the terminal block is removable, rewiring is unnecessary when replacing the controller.
Name change: DI 10 Servo OFF → Emergency. This signal is normally(under control) OFF, and
if input is ON, turns OFF the servo output. For details, refer to Figure 1-23 TB-2 Functions .
Signal addition: DI 11 temperature up completion. This signal is normally(under control) OFF, and
if input is ON, turns OFF the servo output. (Please turn ON when the resin is sufficiently warmed
up and it becomes operable.) Please refer to Figure 1-23 TB-2 Functions for details.
serial communication function