© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
38
MRJ06301
SPAN
When zero setting is completed, the highlight will indicate [Span] (Figure 1-41). [Span] is the maximum
value of the die gap opening (100% on the profile). The die gap core designer checks the [DCDT voltage]
indicator and turns the rotary knob clockwise (CW) to the value of the opening to be specified and set it.
At this time, when the servo valve current starts to move greatly, it means that it has reached mechanical
stop position. In that case, rotate the rotary knob in the opposite direction again and look for where the
servo valve current returns to near the center.
When the required die gap maximum opening has been reached, press [SET] and finish setting the span.
The highlight moves to [Unit].
If you do not do zero and span on the DCDT setting screen, do not move the cursor by touching
the [SET] key. If [SET] is pressed while [Zero], [Span] is highlighted, the current DCDT position
will be reflected to zero and span. To move highlighted parameter, please use the up / down
(
△▽
) key or directly touch the desired parameter.
Unit and Stroke
When [Span] is highlighted, touch [SET] or the cursor down
key, the cursor will move to [Unit] (% or mm).
“%” Is set to
100% as the distance indicated in [Stroke] and displayed on
the profile screen as reference.
“mm”, set the profile directly
in mm based on Span setting. Select the desired unit with
the rotaly knob and press [SET]. The value of [Stroke] sets
0 to 100% stroke length of DCDT. Measure 0-100% move-
ment amount with a ruler and input it. The value set here,
100% = Stroke (mm) is displayed on the profile screen as a
reference for the die gap opening.
After completing the setting, move the cursor to [Back] as
shown in Figure 1-42 and press [SET] or directly touch
[Back] on the screen to move up one screen.
Figure 1-42 Back