© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
18
MRJ06301
1-6.
ELECTRICAL INSTALLATION
1-6-1. GENERAL
Electrical installation includes several phases of work:
A) mounting the DigiPack
Ⅲ
in a suitable location
B) determining the correct phasing so the servovalve, tooling position transducer and, possibly,
accumulator position transducer may be connected to the DigiPack
Ⅲ
C) determining the blow molding machine interface interaction with the DigiPack
Ⅱ
and then
wiring the machine-DigiPack
Ⅲ
interface
D) connect the DigiPack
Ⅲ
to electrical power supply from the stable 24VDC
DigiPack
Ⅲ
MOUNTING
The DigiPack
Ⅲ
must be mounted in a location free of vibration, with protection from the environment and
most important, located in a position allowing the operator and setup man easy visual and physical access.
It is recommended that the mounting be on a swing out panel allowing easy access to the front and back
sides of the DigiPack3.
Mounting information is shown in
“Figure 1-17”. Brackets providing simple panel mounting are included.
All wiring from the DigiPack
Ⅲ
must be shielded. The shield is to be grounded to the DigiPack
Ⅲ
ground at the DigiPack
Ⅲ
only Any other ground paths may cause damage.
1-6-2. REAR CONNECTOR
The rear connector of DigiPack
Ⅲ
can be detached. When installing the connector, secure with the lock
lever. See Figure 1-16.
Figure 1-16 REAR CONNECTOR
Lock lever
Please lock securely
when fixing the con-
nector.
TB-3
:
Power connector
(Screw diameter 3.0 mm,
tightening torque 0.6 Nm)
Reference wiring
diagram
Ethernet Plug
TB-1
:
Base connector
Connector removal status
(Screw diameter 3.5 mm,
tightening torque 1.0 Nm)
Release
Lock
TB-2
:
Connector
installation state
Desorption