MRJ06301
About EMC Standard
1.
Safety standard
Notes to certified of EC directive
J141-215 DigiPack
Ⅲ
is a device incorporated in customer's equipment (blow molding machine) and we
are conducting EMC test against EC Directive within the scope of embedded equipment, but the J141-215
DigiPack
Ⅲ
use by itself is not compatible with the EC Directive.
When customer completes the equipment with J141-215 and use it within Europe or shipment to the area
within European region as the final product, please be sure to check certified of EC Directive by customer
self.
Applicable directive and relative standard.
J141-215 is conducting the EMC test conforming to the EC directive below. It shows directives and related
standards.
EC Directive: EMC Directive 2014/30/EU
Relative Standard:
EN 61000-6-2:2005
IEC61000-4-2~6
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards
- Immunity for industrial environments
EN61000-6-4:2007+A1:2011
Industrial, scientific and medical equipment - Radio-frequency dis-
turbance characteristics - Limits and methods of measurement
2.
Measures EMC
In order to applicable EMC directive, please takes suitable measure against EMC with a customer's blow
molding machine.
And also, when include J141-215 in apparatus and it is used, please consider wire connection and ground-
ing.
The cable used for each wire connection recommends use of a shielded cable.
A shielded cable should be connected to the terminal of J141-215, and the length of skin wire processing