© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
75
MRJ06301
2.5.6.3.
INTERFACE DATA STRUCTURE (32 bits)
Actual digital I/O is the state of the rear terminal block. When the communication virtual input
function is invalid, the communication virtual input pattern is ignored and it operates only with
the actual digital input. When the communication virtual input function is enabled, it is the
logical sum (OR) of the close state between the communication virtual input and the actual
digital input. Please note that it will be recognized as closed if either one is closed.
2.5.6.4.
INTERFACE DATA SETTING (Edge setting)
bit ... 2 Hexadecimal digits. Specify the operation target bit with 00 to 09. Bits other than the operation
target bit do not change. The number is as shown in the table of input in 2.5.6.3.
This “IX” command enables the communication virtual input function and indirectly manipulates the bit.
After edge operation, the bit for communication virtual input is set to 0.
※
The operation when an “IS” command or “IX” command is executed on the same bit within 2 [ms] after
edge s
etting with the “IX” command is undefined.
To set them consecutively, leave at least 2 [msec] interval. (It is not necessary when manipulating another
bit with the “IX” command.)
2.5.6.5.
INTERFACE DATA SETTING (Level setting)
bit ... 2 Hexadecimal digits. Specify the operation target bit with 00 to 09. Bits other than the operation
target bit do not change. The number is as shown in the table of input in 2.5.6.3.
Level ... 2 hexadecimal digits. 00 = Open, Other than 00 = Closed.
31
30
29
28
27
26
25
24
23
22
21
20
↑
↑
↑
※
Writing to bits that can only be acquired is ignored.
17
16
15
14
1
0
Communication virtual input pattern (10bits)
Actual digital Input pattern (10bits, only acquisition possible)
Actual digital Output pattern (10bits, only acquisition possible)
Communication virtual input function 0 ... invalid / 1 ... Valid
7
6
5
4
3
2
13
12
11
10
9
8
19
18
Digital output mode 0 ... AUTO / 1 ... MANUAL
※
Setting on the F4 Monitor screen (Acquisition only possible)
Communication virtual & actual digital input pattern 0 ... open / 1 ... Close
Actual digital output pattern 0 ... open / 1 ... Close
bit 9
E-Stop Signal input
bit 9
End of extrusion Relay status
bit 7
(No assignment)
bit 7
End of extrusion Signal output
bit 8
Start slope Signal input
bit 8
End of filling Relay status
bit 5
(
No assignment
)
bit 5
(No assignment)
bit 6
(No assignment)
bit 6
End of filling
信号出力
bit 3
Stop Signal input
bit 3
Ready Signal output
bit 4
Temp-OK Signal input
bit 4
Alarm Signal output
bit 1
Die gap Signal input
bit 1
(No assignment)
bit 2
Reset Signal input (Do not reset by communication setting)
bit 2
End of Start slope Signal output
bit 0
Start Signal input
bit 0
Maker out Signal output
0
1
2
3
I
X
0
1
2
3
I
X
PC
→
DigiPack
Ⅲ
bit
DigiPack
Ⅲ→
PC
Error
0
1
2
3
4
5
I
X
0
1
2
3
I
X
PC
→
DigiPack
Ⅲ
bit
DigiPack
Ⅲ→
PC
Error
Level