MRJ06301
1.9.2.2.
MACHINE SETTING (SHIFT
→
F4) FUNCTION
Profile points
It is possible to specify the number of set points in the profile display (F1) from
[10/25/30/50/(*)100/200 / Custom]. When [Custom] is specified, it is possible
to specify the number of profile points freely between 10 and 200 points.
Profile interpolation
Sets a interpolation (*)Straight or Spline on the profile display (F1)
Language
Language
– ((*)English/ Chinese / Japanese) Sets the language used on the
LCD Display
Back light (min)
Sets the timer of screen saver. 5, 10, (*)30 min or non screen saver.
LCD
Adjust the screen brightness. Knob CCW : dark, Knob CW : bright
Memory
Select actual feedback line indicated on profile display. (*)ON : Show, OFF :
Not Show
Password
Sets to enable or disable of password protection at the migration of setting
screen.
(*) ON: Enabled, OFF: Disable * When disabled, there is no protection for
setting screen transition.
Machine Type
Machine type
– Accumulator or (*)Continuous
Servovalve type
Servovalve type
– EFB or (*)MFB
Valve current
Valve current of MFB type
– 10, 20, 50 or (*)100 mA
Open command
Cursor move admission to Open command on Monitor display (F4) Enable or
(*)Disable
Marked as (*) is initial setting with new DigiPack
Ⅲ
shipped.
When “Profile Points” is changed, if the value is not specified in the original profile at the final
point of the new profile (for example, 25th points of when specified 25 points) If it was interpo-
lated value, the new 25th point in the profile is specified as the height "0". Also, when the
number of profile points is increased (Example 100 to 200), the profile of the newly added part
is specified as the height "0". See Figure 1-36
Figure 1-36 Example of profile points change