![Moduline GCE060D Original Instructions Manual Download Page 20](http://html1.mh-extra.com/html/moduline/gce060d/gce060d_original-instructions-manual_1818386020.webp)
USA Ed. 1116
11.3 • MANUAL - COOKING CYCLE: TIMED STEAM
Upon the equipment startup, it’s displayed a screen
as shown in the figure.
by default, it is set a convection manual program with
single timed cycle.
To set the steam mode, press the STEAM button
(shown by the arrow in the figure).
To change the temperature in the cavity, press the CA-
VITY TEMPERATURE button and change the value by
turning the knob (to the right to increase, to the left to
decrease). Once you reach the desired value, confirm
by pressing ENTER.
NOTE - The new temperature that you want to set will
continue to flash until it is confirmed. If this is not
done within a few seconds, the program will revert to
the previous value. You can set a temperature betwe-
en 30°C and 130°C (86°F and 266°F).
Then set the time; press the PRObE / TIME button
and turn the knob to enter the desired value. Press
ENTER to confirm.
NOTE - The new time that you want to set will con-
tinue to flash until it is confirmed. If this is not done
within a few seconds, the program will revert to the
previous value.
NOTE - To set an INF (endless) time, turn the knob to
the left, endless mode appears after the 0:00 time.
NOTE - Time has priority over the chamber, so as
soon as the set time is reached, the cycle will finish
even if the temperature in the chamber has not rea-
ched the set value.
NOTE - In steam mode, the humidity is set to its ma-
ximum value (FH) and you cannot edit it.
NOTE - While running a program, you can manually
inject humidification water: when a program is run-
ning, press the HUMIDITY button. The humidity value
displayed flashes, so press the HUMIDITY button
again and hold it down. The equipment injects humi-
dification water until the button is released.
20
Summary of Contents for GCE060D
Page 53: ...USA Ed 1116 53 ...