© MOBATIME
25 / 52
801314.00
P8
Clock address for IR
remote control and
the serial protocols
1-
99
0
-31,
L
(listen only) at SI version
0
-15 - at WTD version
P9
IR controller
autolock
1-60,
U
("automatic lock" is OFF)
Time in minutes for "automatic lock" since the last depression of
button on the IR unit
P10
Time format display
1
-2
1
time with leading zero
2
time without leading zero
P11
Date format display 1-
2
1
date with leading zero
2
date without leading zero
P12
Temperature format
display
°C
°F
P13
Protocol for RS232
and RS485
communication
(not used)
1
- IF482
2 - Supervised RS485
3 - DC master
4 - DC slave
5 - TP RS485 master
6 - TP RS485 listener
7 - DC2 slave
8 - TPHB RS485 master
9 - TPHB RS485
listener
10 - ITRON2000
11 -TPHP RS485 master
12 -TPHP RS485 listener
13 -NMEA 0183
P14
Modulation speed
for RS232 and
RS485
(not used)
1-7
1
1 200 Baud
2
2 400 Baud
3
4 800 Baud
4
9 600 Baud
5
19 200 Baud
6
38 400 Baud
7
57 600 Baud
P 15
Transmission
parameters for
RS232 and RS485
(not used)
Number of data bits
8
7
P 16
Number of stop bits
1
2
P 17
Parity
n no parity
o odd
E
even
P 18
Special operation
mode
0
NTP, PoE: IPv4 / IPv6 dualstack
WiFi: not supported
1
NTP, PoE: IPv4
WiFi: IPv4
2
NTP, PoE: IPv6
WiFi: not supported
P19
Network operation
mode
1
multicast (without IP address), WiFi not supported
2*
unicast – network param. defined manually
3*
unicast – network param. defined by DHCPv4