© MOBATIME
30 / 52
801314.00
8
Stopwatch menu table
Program
option
Function
Scope of the values
(default values are printed in bold)
S0
Counting
direction
1
- 4
1
upwards
2 downwards from a time moment set in advance, with stop
at zero
3 downwards from a time moment set in advance until zero,
with automatic restart from a specified time moment
4 downwards from a set time moment, until zero, and
keeping the count into minus value
S1
Control of
intermediate
time periods
(correspondin
g keyboard
keys are
listed in
brackets)
1
– 4
1
S/S
(PB3S)
Alternating START - STOP -„UNFREEZE“ of
DISPLAY
(if it was frozen)
HOLD
(PB1S)
“Freezing” of displaying data with the counter
proceeding in the counting
RES
(PB1L)
Setting the counter to zero in STOP operation
mode, for counting up, and return to a present
value in all other counting mode
2
S/S
(TL3K)
Alternating START - STOP -„UNFREEZE“ of
DISPLAY
(if it was frozen)
HOLD
(PB1S)
The first depression of this button causes the
display to freeze on the respective time
achieved and lets the counter running.
Further activation of the button shows the
intermediate time elapsed from the first
depression of the button.
RES
(PB1L)
Reset of the counter in the STOP mode while
in counting up. Return to a preset value in
other counting modes.
3
S/S
(PB3S)
count up from zero, or from a present value in
countdown mode. Next activation of the
button causes the display to freeze and to
resume the count from zero in counting up, or
from a preset value in countdown mode.
HOLD
(PB1S)
Unfreezing of the display, leaving the counter
to continue in counting
RES
(PB1L)
Counter reset (to zero), or return to a preset
time followed with counter stop
4
S/S
(PB3S)
Triggering the counter
HOLD
(PB1S)
Stopping the counter
RES
(PB1L)
Resetting the counter or return to a preset
time, with counter stop