13.2 Update firmware over Ethernet at NTP version
•
Create a folder on the computer disk and copy "tftpd32.ini", "tftpd32.chm" and
"tftpd32.exe" in it. Copy the file of new firmware "devapp.bin" as well.
•
Run "tftpd32.exe" let only TFTP Server in the window Settings -> Global Settings
set, don’t change other settings.
•
By the Browse key open choice of active directory and find the one which contains
the given firmware
•
Connect to the clock by the windows command
telnet
<ip clock address>
example: telnet 192.168.0.190
•
The page of telnet requesting will appear, after the password entered identification
of current software version and clock MAC address displays.
•
Enter the command
fu
in telnet window for start the automatic update clock firmware
from the "devapp.bin" file.
•
Information about sending file and its progress displays in the tftpd32 programme
window after the command entering. Connection to telnet is ended automatically.
•
Wait about 1 minute after end of sending. Connect the telnet to clock again.
•
After entering the password, check if the firmware version is correct, if it isn’t, it is
necessary to repeat the whole procedure.
•
Close the telnet window and end the program tftpd32 with the command
exit
.