© MOBATIME
15 / 52
801314.00
The display shows the following:
The item to be adjusted
is now blinking
The options for the parameter setup are shown in the clock menu table
(chapter 5).
Function of the pushbuttons in the setup menu mode
PB1S
storage of the current item and move to another menu item
PB1L
storage of values and return into normal display mode, or entry
into the submenu, where it is permitted by the program
PB2S
increase of the current item by 1
PB2L
continuous increase of the current item
PB1L+PB2L
return into normal display mode, without storage of the data
3.2.1 Submenu for user-specific setting of time constants for data switchover
In menu item
P2
(time constants for automatic switching over of values) set value
U,
then by pushing the
PB1L
enter the submenu. The item to be set is blinking.
By pushing the
PB2S
button the adjusted value is increased in steps of 1, by
pushing the
PB2L
button the value will be continuously increased.
The display shows the following:
Enter the time constant for the display of
time in seconds. Push the
PB1S
button
and enter the constant for date display
in seconds.
Push the
PB1S
pushbutton.
The display shows the following:
Enter the time constant for the display
of temperature in seconds. Push the
PB1S
pushbutton and enter the
constant for stopwatch display in
seconds.
By pushing the
PB1L
button are the entered values stored and the clock returns
to the menu item
P2
.
3.2.2 Offset setting for time synchronization
Clocks can run with a defined offset to synchronization source.
In menu item
P4
(synchronization source), push
PB1L
to go to the time
synchronization offset setting submenu.
The setting unit is 1/100 second.
Setting range -9.99 to +9.99.
Push
PB1L
to save the setting and return to menu item
P4
.
Push together
PB1L
and
PB2L
to return to P4 without storage of the data