83
CHAPTER 8 FUNCTION
8
8.6 Scaling F
unction
Ex.
3: When values are set for a channel with the user range 1 of 2 to 10V as follows:
• "CH
Scaling enable/disable setting": "0: Enable"
• "CH
Scaling upper limit value": 8000
• "CH
Scaling lower limit value": 2000
The digital values and scale-converted digital values are as follows:
Digital value
Digital value after scale
conversion
Analog output voltage (V)
-4000
-12000
-6
-1000
-6000
-2
2000
0
2
5000
6000
6
8000
12000
10
10V
-6V
Analog output voltage (V)
Scaling lower limit
value: 2000
Scaling upper limit
value: 8000
0
12000
-12000
-4000
-12288
12287
0V
2V
Scale converted digital value
Digital value