21
Pipe installation
Docking alternatives
Heating system can be constructed in several different ways
combining indoor unit, tank, control unit and other accessories.
For further option information, see page 73.
In the system example shown on the following page, heating,
hot water as well as cooling operation are available.
Additional heating is helpful on the cold day of the year as the
energy from the air is reduced. It is also recommended as back-
up in case the heat pump operation is blocked for any reason
(e.g. ambient temperature exceeds the operation limit of heat
pump).
NOTE
The heating medium side and the hot water side must be
fitted with the necessary safety equipment in accordance
with the applicable regulations.
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
Explanation
AA25 Controller
BT1
Outdoor sensor
1)
BT6
Temperature sensor, hotwater charging
1)
BT7
Temperature sensor, hot water top
1)
BT25
Temperature sensor, external supply line
1)
BT50
Room sensor
BT63
Temperature sensor, external supply line after
electric heater
BT71
Temperature sensor, external return line
1)
GP10
Circulation pump, Heating medium
QN10
Reversing valve, Hot water/Heating medium
2)
EB1 Additional heat
EB1
Immersion heater
KA1
Auxiliary relay/Contactor
2)
EB101 Heat pump system
BP4
Pressure sensor, condensor
3)
BT3
Temperature sensor, return line
3)
BT12
Temperature sensor, condenser supply line
3)
%7
7HPSHUDWXUHVHQVRUÀXLGSLSH
3)
EB101
Heat pump
FL10
Safety valve
GP12
Charge pump
2)
+4
3DUWLFOH¿OWHU
3)
QM1
Drain valve, Heating medium
40
6KXWR൵YDOYH+HDWLQJPHGLXP)ORZ
40
6KXWR൵YDOYH+HDWLQJPHGLXP5HWXUQ
40
6KXWR൵YDOYH
EQ1 Cooling system
BT64
Temperature sensor, cooling supply line
2)
CP6
Single jacket accumulator tank, cooling
GP13
Circulation pump, cooling
QN12
Reversing valve, Cooling/Heating
2)
Miscellaneous
CM1
Expansion vessel closed, Heating medium
&3
%X൵HUYHVVHO
CP10
Accumulator tank with hotwater heating
EB20
Immersion heater
FL2
Safety valve, Heating medium
KA1
Auxiliary relay/Contactor
RN10
Trim valve
1) Included in and supplied with controller
2) Included in and supplied with accessory
3) Included in indoor unit
Summary of Contents for FDCW60VNX-W
Page 2: ......
Page 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Page 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Page 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Page 80: ...78 Technical data RC HY RC HY RC HY ...
Page 83: ...81 Technical data sheet 3 ...
Page 84: ...82 Technical data sheet 4 ...
Page 87: ...85 Technical data sheet 3 ...
Page 88: ...86 Technical data sheet 4 ...
Page 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 90: ...88 Technical data sheet 6 ...
Page 91: ...89 MEMO ...