18
Connecting hot water tank to water main
Ŷ ,QVWDOODPL[LQJYDOYHLIWKHWHPSHUDWXUHH[FHHGV&
Ŷ ,WLVUHFRPPHQGHGWRLQVWDOODWKHUPRVWDWLFPL[LQJYDOYH
for stable temperature hot water supply.
Ŷ &RQQHFWWKHVWRUDJHWDQNWRWKHZDWHUVXSSO\V\VWHPRI
water pressure at least 1 bar and max 10 bar. Install a
pressure reducer if the pressure at the cold water inlet to the
tank is higher than allowed.
Ŷ ,QVWDOO D VDIHW\ YDOYH ZKLFK KDYH D PD[LPXP EDU
opening pressure on the incoming domestic water line
according to outline diagram in order to protect the storage
tank against overpressure. Pressure increases during heating
the water.
Ŷ 'XULQJKHDWLQJWKHZDWHUVPDOODQGWHPSRUDU\ZDWHUÀRZ
from the safety valve can occur, which indicates that the
pressure has increased above the rated value, which
triggered the valve. This may in no way be prevented.
Ŷ 6DIHW\YDOYHGUDLQOLQHVKRXOGEHLQVWDOOHGZLWKDGHFOLQHLQ
an environment free of freezing and remain open to the
atmosphere. The manufacturer is not responsible for
ÀRRGLQJWKHURRPWKURXJKWKHVDIHW\YDOYH
Ŷ %ORFNHGVDIHW\YDOYHFDQFDXVHHTXLSPHQWIDLOXUH'UDLQ
WKHRXWÀRZIURPWKHVDIHW\YDOYHWRWKHVHZHUDJHRUGUDLQ
grate.
Ŷ 6HHVHFWLRQ'RFNLQJVRQSDJHIRURXWOLQHGLDJUDP
Ŷ &RQQHFW WKH ZDWHU VXSSO\ V\VWHP DFFRUGLQJ WR WKH
installation diagram.
Installation diagram of the PT storage tank with one coil.
1
2
2
2
2
6
7
3
8
4
5
DHW
hot water circulation
(optional)
to sewerage
water supply system
1. PT storage tank
&XWR൵YDOYH
3. Safety valve
4. Drain valve
5. Pressure reducer (option, if the pressure in the system
exceeds the allowable value)
6. Strainer
7. Hot water circulating pump
8. Hot water expansion vessel
Information
In order to minimize the flow of water from the safety valve
associated with the thermal expansion of the liquid, it is
advisable to install a suitable expansion vessel at the cold
water connection (see item 8.)
CAUTION
Installation of the appropriate safety valve in the cold
water supply line protecting the unit against
overpressure is mandatory!
CAUTION
Installation of necking of any kind (such as reducers, dirt pockets,
etc.) and cut-off valves between the storage tank and the safety
valve is not allowed. Only a T-pipe with a drain valve and a T-pipe
with an expansion vessel may be installed in these line sections.
CAUTION
Never block the safety valve or drain line. This can cause
a dangerous overpressure in the storage tank.
CAUTION
When heating water, slight, temporary discharge from
the safety valve can occur. This is a correct safety valve
function. Any attempt to interfere in its operati on can
lead to the danger and destruction of the storage tank.
CAUTION
Never use the equipment with clogged safety valves.
Connection
After the installation and levelling the tank, follow the proce-
GXUHEHORZIRUWKHFRQQHFWRUSLSHV\PEROVUHIHUWRSDJH
1. Remove protecting plugs from the connector pipes
2. Connect the hot water intake line (N).
3. Connect the cold water supply line together with the
required safety valves (G).
4. If the system has the hot water circulation system, connect
it to the connector pipe (L). Otherwise, plug the pipe.
5. Connect the supply (J) and return (H) of the heating
medium to the coil.
CAUTION
If there is an electric heating module installed in the
storage tank, fill the tank with water before connecting
it to the electrical installation.
Pipe installation
Summary of Contents for FDCW60VNX-W
Page 2: ......
Page 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Page 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Page 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Page 80: ...78 Technical data RC HY RC HY RC HY ...
Page 83: ...81 Technical data sheet 3 ...
Page 84: ...82 Technical data sheet 4 ...
Page 87: ...85 Technical data sheet 3 ...
Page 88: ...86 Technical data sheet 4 ...
Page 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 90: ...88 Technical data sheet 6 ...
Page 91: ...89 MEMO ...