58
Control
Menu 5.1.3 - max diff flow line temp.
max diff compressor
Setting range: 1 – 25 °C
Default value: 10 °C
max diff addition
Setting range: 1 – 24 °C
Default value: 7 °C
Here you set the maximum permitted difference between the
calculated and actual supply temperature during compressor
PRGHDQGDGGKHDWPRGH0D[GL൵DGGLWLRQDOKHDWFDQQHYHU
H[FHHGPD[GL൵FRPSUHVVRU
max diff compressor
When the current supply temperature
deviates
from the set
value compared to that calculated, the heat pump is forced to
stop irrespective of the degreeminute value.
,IWKHFXUUHQWVXSSO\WHPSHUDWXUHH[FHHGVWKHFDOFXODWHGÀRZ
temperature plus the set value, the degree minute value is set to
0. The compressor in the heat pump stops when there is only a
heating demand.
max diff addition
If "addition” is selected and activated in menu 4.2 and the
present supply temp exceeds the calculated temperature plus
the set value, the additional heat is forced to stop.
Menu 5.1.4 - alarm actions
Select how to control the heat pump in the event of an alarm.
You can choose to stop producing hot water and/or reduce the
room temperature.
CAUTION
If no alarm action is selected, it can result in
higher energy consumption in the event of an
alarm.
Menu 5.1.12 - addition
add type: step controlled
max step
Setting range (binary stepping deactivated): 0 – 3
Setting range (binary stepping activated): 0 – 7
Default value: 3
fuse size
Setting range: 1 – 200 A
Factory setting: 16 A
You can set the maximum number of permitted additional
heat steps, if there is internal additional heat in the tank (only
accessible if the additional heat is positioned after QN10),
whether binary stepping is to be used and the size of the
fuse.
<Add. Type: shunt controlled (RC-HY40 only)>
prioritised additional heat
6HWWLQJUDQJHRQR൵
)DFWRU\VHWWLQJR൵
minimum running time
Setting range: 0 – 48 h
Default value: 12 h
min temp.
Setting range: 5 – 90 °C
Default value: 55 °C
mixing valve amplifier
Setting range: 0.1 –10.0
Default value: 1.0
mixing valve step delay
Setting range: 10 – 300 s
Default values: 30 s
fuse size
Setting range: 1 – 200 A
Factory setting: 16 A
transformation ratio
Setting range: 300 – 3000
Factory setting: 300
Select this option if shunt controlled additional heat is
connected.
Set when the addition is to start, the minimum run time and the
minimum temperature for external addition with shunt here.
External addition with shunt is for example a wood/oil/gas/
pellet boiler.
<RXFDQVHWVKXQWYDOYHDPSOL¿FDWLRQDQGVKXQWYDOYHZDLWLQJ
time.
Selecting "prioritised additional heat" uses the heat from the
external additional heat instead of the heat pump.
The shunt valve is regulated as long as heat is available,
otherwise the shunt valve is closed.
TIP
See the accessory installation instructions for function
description.
Menu 5.1.14 - flow set. climate system
presettings
6HWWLQJUDQJHUDGLDWRUÀRRUKHDWUDGÀRRUKHDW
Default value: radiator
Setting range DOT: -40.0 – 20.0 °C
The factory setting of DOT value depends on the country
that has been given for the product's location.
The example below refers to Sweden.
Factory setting DOT: -20.0 °C
own setting
Setting range dT at DOT: 0.0 – 25.0
Summary of Contents for FDCW60VNX-W
Page 2: ......
Page 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Page 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Page 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Page 80: ...78 Technical data RC HY RC HY RC HY ...
Page 83: ...81 Technical data sheet 3 ...
Page 84: ...82 Technical data sheet 4 ...
Page 87: ...85 Technical data sheet 3 ...
Page 88: ...86 Technical data sheet 4 ...
Page 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 90: ...88 Technical data sheet 6 ...
Page 91: ...89 MEMO ...