49
Commissioning and adjusting
7KH¿JXUHDWWKHHQGRIWKHFXUYHLQGLFDWHVWKHFXUYHQXPEHU
7KH¿JXUHEHVLGHWKHWKHUPRPHWHULFRQJLYHVWKHFXUYHR൵VHW
Use the control knob to set a new value.
&RQ¿UPWKHQHZVHWWLQJE\SUHVVLQJWKH2.EXWWRQ
Curve 0 is an own curve created in menu 1.9.7.
To select another curve (slope):
1.
3UHVV2.EXWWRQWRDFFHVVWKHVHWWLQJPRGH
2.
Select a new curve. The curves are numbered from 0 to 15,
and the bigger number curve has steeper slope.
Curve 0 means that own curve (menu 1.9.7) is used.
3.
3UHVV2.EXWWRQWRH[LWWKHVHWWLQJ
To read off a curve:
1.
Turn the control knob so that the ring on the shaft with the
outdoor temperature is marked.
3UHVV2.EXWWRQ
3.
)ROORZWKHJUH\OLQHXSWRWKHFXUYHDQGRXWWRWKHOHIWWR
UHDGR൵WKHYDOXHIRUWKHVXSSO\WHPSHUDWXUHDWWKHVHOHFWHG
outdoor temperature.
4.
You can now select to take read outs for different outdoor
temperatures by turning the control knob to the right or left
DQGUHDGR൵WKHFRUUHVSRQGLQJÀRZWHPSHUDWXUH
3UHVV2.RU%DFNEXWWRQWRH[LWUHDGR൵PRGH
TIP
Wait 24 hours before making a new setting, so that the
room temperature has time to stabilise.
If it is cold outdoors and the room temperature is too low,
increase the curve slope by one increment.
If it is cold outdoors and the room temperature is too high,
lower the curve slope by one increment.
If it is warm outdoors and the room temperature is too low,
increase the curve offset by one increment.
If it is warm outdoors and the room temperature is too high,
lower the curve offset by one increment.
Hot water circulation setting
hot water recirc.
operating time
Setting range: 1 – 60 min
Default value: 60 min
downtime
Setting range: 0 – 60 min
Default value: 0 min
Set the hot water circulation for up to three periods per day
here. During the set periods the hot water circulation pump will
run according to the settings above.
"operating time" decide how long the hot water circulation
pump must run per operating instance.
"downtime" decide how long the hot water circulation pump
must be stationary between operating instances.
Hot water circulation is activated in menu 5.4 "soft inputs and
outputs".
Summary of Contents for FDCW60VNX-W
Page 2: ......
Page 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Page 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Page 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Page 80: ...78 Technical data RC HY RC HY RC HY ...
Page 83: ...81 Technical data sheet 3 ...
Page 84: ...82 Technical data sheet 4 ...
Page 87: ...85 Technical data sheet 3 ...
Page 88: ...86 Technical data sheet 4 ...
Page 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 90: ...88 Technical data sheet 6 ...
Page 91: ...89 MEMO ...