CHAUFFAGE FIOUL INFRAROUGE 42kw

FUEL INFARED HEATER 42kw

CH 0033

Summary of Contents for CH 0033

Page 1: ...clas com CHAUFFAGE FIOUL INFRAROUGE 42kw FUEL INFARED HEATER 42kw CH 0033...

Page 2: ...sur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation problem...

Page 3: ...e art nr matr reg nr Article Num ro de production Puissance Consommation Courant absorb Fusible Voltage Air aspir Mod le R f Puissance Conso Kg h Combustible R servoir L Puissance moteur W Tens monoph...

Page 4: ...33 CHAUFFAGE FIOUL INFRAROUGE 42kw 4 TETE DE COMBUSTION PRESSION POMPE 9BAR 1 Tete de combustion 2 Porte buse 3 Buse 4 Electrode 5 Vis autotauraudeuse 6 D flecteur 7 Vis 8 Insert filet M4 a eurant la...

Page 5: ...CH 0033 CHAUFFAGE FIOUL INFRAROUGE 42kw 5 Rondelle languette Rondelle Vis Support Vis Washer Bouton Rondelle languette Vis...

Page 6: ...CHAUFFAGE FIOUL INFRAROUGE 42kw 6 SCHEMA ELECTRIQUE ELECTRICAL DIAGRAM P Pompe S Appareillage EV Electrosoupape F Fusible C Interrupteur M Moteur SR Sonde TL Thermostat TA Thermostat ambiant RT Retar...

Page 7: ...eusement toutes les instruc tions fournies afin d apprendre le mode d emploi correct de garantir un rendement optimal et d viter toute faute pouvant engendrer des situations dangereuses Respecter touj...

Page 8: ...l Il faut assurer au local o l appareil marche un renouvellement d air suffisant et l absence de tout r sidu de poussi re gaz ou vapeurs inflammables ou toxiques une temp rature lev e Ne jamais faire...

Page 9: ...ti lateur se met en marche Le cycle automatique d allumage se met en fonction au moyen de la bo te de contr le Apr s qualques secondes de surveillance automatique le g n rateur reste r guli rement en...

Page 10: ...sion V rifier le fusible dans la boite de contr le V rifier si le transformateur est br l L appareil surchauffe pendant son fonctionnement normal Le d bit de carburant est trop lev en raison de l usur...

Page 11: ...odice art nr matr reg nr Article Production number Power Consumption Absorbed current Fuse Voltage Succed air Model Ref Power Cons Kg h Fuel Tank L Engine Power W Phase Voltage Volt Hz Dimensions cm W...

Page 12: ...FUEL INFARED HEATER 42kw 12 COMBUSTION HEAD PUMP PRESSURE 9BAR 1 Combustion head 2 Support nozzle 3 Nozzle 4 Electrode 5 Self tapping screw 6 Head deflector 7 Screw 8 M4 threaded insert flush with th...

Page 13: ...CH 0033 FUEL INFARED HEATER 42kw 13 ASSEMBLY Tab washer Washer Screw Bracket Screw Rondelle Button Tab washer Screw...

Page 14: ...CH 0033 FUEL INFARED HEATER 42kw 14 ELECTRICAL DIAGRAM P Pump S Equipment EV Electrovalve F Fuse C Switch M Motor SR Probe TL Thermostat TA Ambient thermostat RT Timer...

Page 15: ...ngs and people due to the non observance of these indications Before operating the machine carefully read all the instructions provided in order to learn the correct way of using it to guarantee an op...

Page 16: ...ve the air flow and the mixing with the diesel fuel HIGH EFFICIENCY CYLINDRICAL BOILER with combustion chamber entirely made of glass ceramic VENTILATION and cooling unit high capacity with fan with a...

Page 17: ...F switch to the ON position the green light comes on and the fan starts The automatic ignition cycle is started by the control box After a few seconds of automatic monitoring the generator remains in...

Page 18: ...ck the fuse in the control box Check if the transformer is burned The unit overheats during normal operation The fuel flow rate is too high due to nozzle wear or the use of a nozzle with different cha...

Page 19: ...19...

Page 20: ...de votre distributeur agr If you need components or parts please contact the reseller In case of problems please contact your authorized technician CLAS Equipements 83 chemin de la CROUZA 73800 CHIGN...