13
ERROR CODES
13
- 3
13.1 List of Error Messages in CC IE Control Utility
13.1.2 Error messages displayed on the setting screen
13.1.2 Error messages displayed on the setting screen
(1) Parameter setting screen
Error message
Corrective action
Failed to read parameters. The probable causes are:
• Parameters have not been set.
• There is a problem in the operating system.
• Write the parameters.
• Check the H/W failure on the CC-Link IE Controller
Network board.
The network No. setting value is outside the range.
Please input the value within the range 1-239.
Set the value for the network number within the range of 1 to
239.
The group No. setting value is outside the range.
Please input the value within the range 0-32.
Set the value for the group number within the range of 0 to
32.
The station No. setting value is wrong. Please input a value
in the range XX - YY.
Set the value for the station number within the range of XX to
YY.
The channel No. XX is overlapping.
Please correct the settings.
Set the channel numbers not to overlap.
The network No. XX is overlapping.
Please correct the settings.
Set the network numbers not to overlap.
Unable to open the specified file.
• Check the specified file.
• The total number of characters for the file location and file
name should be less than 128.
The specified file is not a CC IE Control utility parameter file. Check the specified file.
The specified file cannot be read.
The utility version is different from the CC IE Control utility
version.
Install the utility same version as the CC IE Control utility in
which the file was created.
Failed to save the parameter file.
Confirm the destination to save.
• Check the free space of the storage location.
• Check the media of the storage location.
• The total number of characters for the storage location and
file name should be less than 128.
Failed to save the file.
Confirm the destination to save.
• Check the free space of the storage location.
• Check the media of the storage location.
• The total number of characters for the storage location and
file name should be less than 128.
Specified file pass exceeds 255 characters.
Please specify it again.
Specify the file pass within the 255 characters.
Failed to write parameters. The probable causes are:
• A Windows logon user does not have administrator
authority.
• The operating system is faulty.
• Check if Windows
®
is logged on as an administrator
authorized user.
• Check the H/W failure on the CC-Link IE Controller
Network board.
An error occurred in CC-Link IE Controller Network board X
during reset.
Error code: XXXX
The probable causes are:
• CC-Link IE Controller Network board is not mounted
properly.
• CC IE Control utility is not installed properly.
• Check whether the CC-Link IE Controller Network board is
installed properly.
• The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.